8 Door Network Controller

8 Door Network Controller

Category: Card Access System
Manufacturer: Smartkey
Function Description
Card Open Door Present card to external wiegand or 485 reader connect via SKDC
Card + PIN Open Door
  1. Direct connect with SK10K-UN / SK100K-UN reader. SKDC is not required
  2. Connect SK10K-UN / SK100K-Un to SKDC
  3. Conect SK10K, SK100K-CN keypad reader to SKDC via wiegand or RS-485 connector
  4. Connect SK100K keypad reader to SKDC via RS-485 connector
  5. Open door either by enter security PIN or Card ID
  6. Open Door by Card + Pin: 4 digits PIN; By Security PIN: 8 digits PIN
Security PIN Open Door
Card ID Open Door
Fingerprint Open Door Connect to SK fingerprint reader via wiegand connector. Access Mode can be set to: Card + Fingerprint, ID + Fingerprint, Fingerprint + PIN, Card + Fingerprint + PIN, ID + Fingerprint + PIN, Card Only, Card + PIN, PIN only, ID only & etc
Super User Card Open Door During system failures, using predefine super user card to open door
Free Wiegand Setting Yes. Able to configure battery low-voltage alarm when using long range reader
Connect External Keypad Reader

Connect via SKDC

  1. HID wiegand keypad reader
  2. SK readers inclusive of SK-10K, SK100K-CN and SK100K keypad reader via wiegand connector
  3. SK10K-UN and SK100K-UN
Connect External SK Fingerprint Reader Yes. via SKDC wiegand connector
Connect to SKDC Connect up to 8 SKDC, controlling 8 doors respectively
Connect to SK8I/O Connect up to 16 SK8I/O. Each consist of 8 DI and 8 DO
Connection to PC
  1. 232, 485 or TCP/IP, use jumper to setup between 232 and 485
  2. Use keypad to setup Controller ID 001-255
  3. Use keypad to set IP Address, Subnet Mask and Gateway
Alarm Functions Support Door Left Open Alarm, Door Force Open Alarm, Temper Alarm and Local TTL Alarm
Door Left Open Alarm 1-255 seconds. Factory default is 5 seconds. Can be disable
Add/Delete Card in Standalone Mode Yes
Dual-card Verification Yes
Wrong PIN Control During Card + PIN operation, if PIN enter incorrectly for predefine times, controller will be disabled for a predefine duration
Same Card Delay 0-255 seconds. Factory default is 0 second
Time Zone Control 32 set of timezone
Holiday Control Yes
Lost / inhabit Card Yes
Card Start and Expiry Date Validation Yes
Door Auto Unlock by Timezone Yes
Connect External Printer Yes
Anti-passback Yes (Local or Global). Able to reset manually or by time
Card Number Output Byte 1-4 bytes. Default is 4 bytes
Card Number Display Format HEX, DEC, ABA, User code. Default is DEC
Communication Monitoring Yes
Tamper Alarm Yes
Power Supply Monitoring Main power failure alert and backup battery low voltage alert
Timezone Control Able to set to Exit without Timezone control. Factory default is Yes
Door Sensor Setup Door sensor setup including connection type, sensitivity, smart door lock control and record with confirm
External Backup Battery with Charging Capability Yes
AddThis Social Bookmark Button