2 / 4 Door Controller

2 / 4 Door Controller

Category: Card Access System
Manufacturer: Smartkey
Function Description
Card Open Door Present card to external wiegand or 485 reader
Card + PIN Open Door
  1. Connect with SK10K, SK100K-CN keypad reader via wiegand or RS-485 connector
  2. Connect to external SK100K keypad reader via RS-485 connector
  3. Open door either by enter security PIN or Card ID
  4. Open Door by Card + Pin: 4 digits PIN; By Security PIN: 8 digits PIN
Security PIN Open Door
Card ID Open Door
Fingerprint Open Door Connect to SK fingerprint reader via wiegand connector. Access Mode can be set to: Card + Fingerprint, ID + Fingerprint, Fingerprint + PIN, Card + Fingerprint + PIN, ID + Fingerprint + PIN, Card Only, Card + PIN, PIN only, ID only & etc
Connect External Wiegand Reader Support any 26/34 bit wiegand card reader and free wiegand card reader
Free Wiegand Setting Yes. Able to configure battery low-voltage alarm when using long range reader
Connect External Keypad Reader
  1. HID wiegand keypad reader
  2. SK range readers inclusive of SK-10K, SK100K-CN keypad reader and SK100K keypad reader
Connet External SK Fingerprint Reader Yes, via wiegand port
Connection to PC via RS232, RS485 or TCP/IP (require TCP/IP converter)
Exit by Push Button Yes
Door Force Open Alarm Yes

Door Held Open Alarm

1-255 seconds. Factory default is 5 seconds. Alarm output can be disable
Add/Delete Card in Standalone Mode Yes
Multi-card Verification Yes, up to 8 cards
Keypad Open Door Through controller keypad.
Wrong PIN Control By flow control. Able to setup PIN enter incorrectly to lockout controller or reader
Same Card Delay 0-255 seconds. Factory default is 0 second
Time Zone Control 32 set of timezone
Holiday Control Yes
Lost / inhabit Card Yes
Card Start and Expiry Date Validation Yes
Door Auto Unlock by Timezone Yes
Connect External Printer Yes
Dynamic Storage Adjustment Yes
Alarm and Event Output via 3rd Serial Port
Anti-passback Yes (Local or Global). Able to reset manually or by time
Timing Event (Alarm Clock) Yes
Alarm arming / disarm Yes
Anti Tailgating Yes
Time Error Correction Yes
Card Number Output Byte 1-4 bytes. Default is 4 bytes
Card Number Display Format HEX, DEC, ABA, User code. Default is DEC
Communication Monitoring Yes
Internal Buzzer Alarm Able to setup trigger alarm buzzer when door force open or door held open alarm. Factory default is "No"
PIN Control Able to setup Exit without PIN control. Factory default is Yes
Timezone Control Able to set to Exit without Timezone control. Factory default is Yes
Tamper Alarm Build-in tamper switch. If device is opened, controller will send an alarm record to back end PC
Door Left Open Restore transaction Yes
485 Comm Terminating Resistor via Jumper setting
Auto Monitoring Yes (Auto DI)
Auto Control Yes (Auto DO)
Flow Control Yes
485 Reader ID Able to modify 485 Reader ID via controller
Reader & Controller Releation Able to modify
Door Sensor Alarm Channel Able to modify
Cancel TTL changes follow door sensor Yes
Door Interlock Able to setup 2 or more interlocking door